Control elements

A
A Operating field
B Thermostat "hot water"
C Temperature regulator "steam stage" (upgrade kit for steam
stage only)
Operating field
Unlocking burner faults
 Press the key for releasing the burner fault.
Info mode
Note: The info mode can be called up only during the operating
mode in each state of the burner.
 Press the key for approx. 0.5 seconds.
You will see a display with an info number and a value dis-
played after it.
Example: Consumed fuel = 1772 l/m
–weishaupt–
Info No.
Displayed value
0
Consumed fuel (captured via the input of the im-
pulse counter)
1
Operating hours Stage 1
2
Operating hours Stage 2
3
Number of burner starts that have been carried out
4
Software no. of the firing manager
5
Creation date of the software
6
Appliance no.:
7
Appliance testing date
8
Current eBUS address
9
Oil monitoring function
10
Current eBUS address of regulator
C
B
3
3
l/m
The system goes back to displaying the operating status after info
number 10 or if there is a waiting period of 20 seconds.
To go to the next information:
 Press the key for approx. 0.2 seconds.
Service mode
Note: The service mode may only be accessed by Customer Ser-
vice.
Remote control (optional)
Not-Aus
1
Temp.
kalt heiß
2
Störung
3
A
(A) Remote control without steam operations
1 Emergency-stop button
2 Temperature
2a cold
2b hot
3 Fault
(B) Remote control with steam operations
1 Emergency-stop button
2 Operating mode
2a Water operations
2b Steam operations
3 Temperature
3a cold
3b hot
– For connection values, see technical data and type plate.
– The electrical connections must be done by an electrician ac-
cording to IEC 60364-1.
Making the plant ready for operations
 Check high pressure hose, pipe connections, fittings and wa-
ter jet for damage every time before use.
 Check hose coupling to ensure that it sits firmly and is leak-
proof.
Switch-off in case of emergency
 Press the factory-recommended main switch for emergency
stop of the main plant or the emergency stop switch of the en-
try to the heating room.
 Shut off water supply.
 In hand spray operations, press the hand-spray gun until the
plant is pressure-less.
 Close the fuel supply tap.
6
-
EN
Not-Aus
1
2a
Betrieb
Wasser Dampf
2
2b
Temp.
kalt heiß
3
B

Start up

Power connection

Operation

2a
2b
3a
3b
29