INSTALLATION GUIDE
Leaving about 1meter extra wire, peg the wire along the boundary from the rear side of the
charging station with a distance of the pegs of 80cm. When you finish the layout and back
to the charging station, leave another 1meter extra wire and then cut it.
Make sure if a square corner is uncounted in your working zone, please do not create
a 90deg sharp corner as below, the Mower will turn here anyway and cut this area as it
turns, so best leave a 45deg angle in each corner see below.
If the boundary wire is required to protect a flower bed or other obstacle within the Working
area then please follow this suggestion. The boundary wire should be laid from the main
Boundary in a straight line as shown then around the profile of the obstacle and then back
to the main boundary again, the gap between the two boundary wires shown should be
as close as possible without crossing. The same peg can be used to fix them; the YARD
FORCE Robotic Lawnmower will mow freely over the double wire.
If you find you do not have enough Boundary wire left to go around the whole area you
wish to protect exclude from cutting or if you need to make some changes later then
spare wire can be purchased and it is easy to connect with the provided Boundary wire
connectors ( Item 18).
4.5. Prepare the boundary Wire For the Charging Station
After laying the boundary wire you need a decrustation pliers (See below left photo) or
scissor to clear the teflon cover of the wire and explode the metal threads for connection
to the charging station. A length of 10 - 15 mm metal exploring metal threads are
recommended. You may twist the end of the metal threads with your fingers to make it
tight for connection.
NO
OK
10 - 15 mm
28
INSTALLATION GUIDE
4.6. Connect the Charging Station With the Boundary Wire
Once connectors have been prepared to each of the two boundary wire ends then these 
can be connected to the charging station as shown below. It is important to lay the wire 
from the front of the charging station underneath the base to protect it before connecting 
at the rear. This connector should then be connected to the Left hand tab marked "F", and
the rear boundary wire connector is connected to the Right hand tab marked "B".
IMPORTANT INFORMATION
Double check that the charger connections are as shown below. Even if it is blue light the
connectors are wrongly connected the machine will not work.
NOTE !
When the working area is less than 100 m
40 m, please connect a 10 Ω / 20 W cement resistance to the boundary wire, or contact
the service.
After connecting the "F" and "B" connectors to the charging station, the charging station
can be fixed down with the boundary pegs(item 15). Please ensure before this is done that
the charging station is still situated on a flat surface and mains connection is still can be
reached. Also ensure that 2m of straight boundary wire is in front and 1 m to rear of station
and any surplus boundary cable is tucked under the charging station base to protect it.
Once this is done, Connect the charger extension cable (Item 14) to Charging base,
meanwhile ensuring that the power supply is not connected to mains voltage just yet.
Once these connections are made, plug in power supply, there is a blue LED Light on
Connector F