15. Starting the heater automatically AutoOn
This function is used if you want the heater to start
automatically at a later time. The heater works for 24
hours and then stops.
Automatic start is repeated the following week as long
as the function is activated.
1 Press the button with the arrow
until the AutoOn symbol flashes.
"OFF" is shown in the display.
To activate AutoOn, press the +/
On button or the -/Off button
to close the function.
blinkar
flashes
When you get to the vehicle and AutoOn is activated,
de-activate AutoOn so that the heater does not stop
after 24 hours (the boiler cannot be switched off when
AutoOn is activated).
16. Load monitor Amp
This function is used if you do not want the 230V fuses
to become overloaded. If the vehicle's total current
consumption exceeds the set value, the boiler's
electrical power will be automatically reduced.
On account of voltage variations and tolerances, one
can select various control levels (for example, for 6A
fuse, one can choose either 5,6,7 Amp setting).
If the fuse does not hold, select a lower set value.
1 Press the button with the arrow
until the Amp symbol flashes.
"OFF" is shown in the display.
blinkar
flashes
10
GB
 The start time will be displayed.
Set the time in accordance
with item 12 and press "Store"
to store the settings. "OFF" is
shown in the display.
 Press the -/Off button to
activate and set the function.
The following values can be
set with +/On or -/Off buttons,
5,6,7,9,10,11,15,16,17.
To activate the function you must first light up the lower
row of functions (see item 11).
The function controls the panel's main breaker.
3 Press the +/On button. On is
shown in the display and AutoOn
flashes. Set the panel's main
breaker to OFF.
You can then step back with the left-hand button in the
settings and press Store in all positions.
The function is disconnected in the factory setting.
To activate the function, you must first light up the
lower row of functions (see item 11).
3 Amp is shown in the display
when the panel returns to
standby.
blinkar
flashes