Herunterladen Inhalt Inhalt Diese Seite drucken

Bender ISOMETER isoPV425 Kurzanleitung Seite 28

Isolationsüberwachungsgerät für ungeerdete dc-stromkreise (it-systeme) für photovoltaik-anlagen bis 3(n)ac, ac 690 v / dc 1000 v/mit ankoppelgerät agh420
Vorschau ausblenden Andere Handbücher für ISOMETER isoPV425:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3)................................................................................................................................ 3M4
Transport (IEC 60721-3-2) ....................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1) ........................................................................................................................ 1M3
Connection
Connection type...............................................................................................................Screw or push-wire terminals
Screw terminals:
Nominal current....................................................................................................................................................≤ 10 A
Tightening torque ...............................................................................................................0,5...0,6 Nm (5...7 lb-in)
Conductor sizes .............................................................................................................................................AWG 24-12
Stripping length.......................................................................................................................................................8 mm
Rigid / flexible .........................................................................................................................................0.2...2.5 mm
Flexible with ferrules with / without plastic collar ..............................................................................0.25...2.5 mm
Multiple conductor rigid .........................................................................................................................0.2...1.5 mm
Multiple conductor flexible.....................................................................................................................0.2...1.5 mm
Multiple conductor with ferrules without plastic collar ......................................................................0.25...1.5 mm
Multiple conductor with TWIN ferrules with plastic collars ................................................................0.25...1.5 mm
Push-wire terminals:
Nominal current....................................................................................................................................................≤ 10 A
Conductor sizes .............................................................................................................................................AWG 24-14
Stripping length ....................................................................................................................................................10 mm
Rigid.........................................................................................................................................................0.2...2.5 mm
Flexible without ferrules .......................................................................................................................0.75...2.5 mm
Flexible with ferrules with / without plastic collar ..............................................................................0.25...2.5 mm
Multiple conductor with TWIN ferrules with plastic collars ..................................................................0.5...1.5 mm
Opening force ........................................................................................................................................................... 50 N
Test opening, diameter .......................................................................................................................................2.1 mm
Connection type ................................................................................................................Terminals Up, AK1, GND, AK2
Single cables for terminals Up, AK1, GND, AK2:
Cable lengths...................................................................................................................................................... ≤ 0.5 m
Connection properties ....................................................................................... ≥ 0.75 mm
Other
Operating mode............................................................................................................................ Continuous operation
28