Herunterladen Inhalt Inhalt Diese Seite drucken

Configuration For Rpt; Connection In The Home Network - CitrinSolar CS WebBox2 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.1
Configuration for RPT
In order to use RPT, the Bus.net access over the local network has to be
enabled, see chap. 7.17 on page 36.
With a VBus.net account you can easily use RPT in order to parameterise the
controller:
Î In the VBus.net menu My Devices, click on Edit.
Î On the General settings page, tick the option Allow parameterization
using the via address and the RESOL Parameterization tool (RPt).
Î Enter the Via tag from the VBus.net menu item General settings into the RPT
field URL/IP.
Î Enter the password into the Password field.
5.1.1 Connect.Direct connection via WLAN (service access)
Connecting devices directly to the Communication module over WLAN
Note
Before using the WLAN, make sure that the WLAN country setting is
correct, see chap. 7.14 on page 34.
The WLAN allows the installer to directly connect with the Communication mod-
ule without having to access the LAN network of the customer. All access data
required can be found on the back of the housing.
In order to connect computers and other devices such as smartphones to the
Communication module via WLAN, proceed as follows:
Î If the WLAN LED is not illuminated, briefly press the button.
WLAN will be activated.
Î Select the WLAN network of the Communication module on your smartphone
and enter the network name (SSID).
The network name can be read in the Configuration / Network menu under
Access point settings. The default SSID name is KM2-{12-digit serial number}.
Î Click Connect.
Î Enter the WLAN code of the Communication module.
This code can be read from the label on the back side of the housing (WLAN-AP).
Î Establish the connection.
After the WLAN connection with the Communication module has been estab-
lished, the Web interface can be reached with an Internet browser under the IP
address http://192.168.240.1 or the controller can be parameterised over RPT.
If you access the website in its encrypted version (https), a security enquiry can
appear. You can either ignore this warning or access the unencrypted version (http).
DeviceDiscovery will not be necessary.
Web-Inter. admin XxXxXxXxX
WLAN-AP -
xxxxxxxx
SSH
root xXxXXXX

5.1.2 Connection in the home network

The Communication module can be connected to the home network via LAN, in
order to access the controller with the RPT Parameterisation Tool or to configure
the Communication module over the Web interface. For further information, see:
chap. 3.3 (W)LAN connection on page 26
chap. 6 Finding the Communication module in the network on page 31
chap. 7.12 Network configuration on page 34
chap. 7.17 Configuring the remote access on page 36