To stop the machine, release the Foot pedal
switch (10). Push the red OFF­switch (1) to turn
the machine off.
Tilting the table
Fig. A, D
The scroll saw table can be tilted from 0 to 45°.
To do so:
• Untighten the Angle adjustment knob (2) by
turning it anti­clockwise.
• Manually tilt the table until the desired angle
has been reached (see the graduated scale on
the machine).
• Retighten the Angle adjustment knob (2) by
turning it clockwise.
Removing the saw blade
Fig. E
Always disconnect the machine from the
main power supply before carrying out
any maintenance work.
• Untighten the Spanner (6) by turning it
clockwise until the spring is slack.
• Pull the Table inlay (9) upwards out of the saw
table to achieve a clear view of the blade, as
shown on fig. E1.
• Carefully push down the upper saw­blade
holder and slightly lift the blade in order to
facilitate its removal, as shown on fig. E2.
• Allow the blade to drop down slightly and push
it forward, in order to loosen it from the lower
holder.
Installing the saw blade
Fig. E
Always disconnect the machine from the
main power supply before carrying out
any maintenance work.
Use universal saw blades from any
better DIY shop or machine shop.
• Select the correct blade for the kind of wood to
be cut.
• Untighten the Spanner (6) by turning it
clockwise until the spring is slack.
• Pull the Table inlay (9) upwards out of the saw
table to achieve a clear view of the blade, as
shown on fig. E1.
• Push the saw blade through the slot, with the
teeth pointing downwards. Make sure that the
bolt of the saw blade (or saw­blade adapter)
slides into the lower saw blade holder.
• Pull the saw blade up, so that the upper bolt
(or saw­blade adapter) slides into the upper
holder.
• Push the Table inlay (9) downwards into the
saw table.
• Retighten the Spanner (6) by turning it anti­
clockwise until the saw blade has the required
tension.
• Remove all tools and other objects from the
saw table. Activate the current and allow the
saw blade to run before starting to saw.
The saw blade should run quietly.
Adjusting the saw blade position
Fig. F
The saw blade can be mounted in two different
positions: regular frontal position as shown on
Fig. F1 and in sideways position as shown on
Fig. F2. When using the sideways position, even
longer workpieces ca be sawed with ease.
Adapters for universal saw blades
Fig. G
The enclosed adapters should only be used with
universal (= without pins on the end) saw blades
• Unscrew the Allen screws on the adapter anti­
clockwise as shown on fig. G1
• Slide the universal saw into the gap between
the Allen screws
• Tighten the Allen screws clockwise so the saw
is clamped
• Install the saw blade (see INSTALLING THE
SAW BLADE) on the saw blade holders as
shown on fig. G2
Workpiece holder
Fig. A, H
The workpiece holder (8) is used to hold the
workpiece to the saw table, preventing the
workpiece from moving up and down due to the
movement of the blade. The workpiece holder
must be adjusted in height depending on the
thickness of the workpiece.
• Untighten the Locking knob (12) by turning it
anti­clockwise.
• Adjust the height of the Workpiece holder (8) to
the desired height.