7.3 Installation in glass doors or windows

When working with cut glass always wear protective gloves as the edges may be sharp.
The
SureFlap
Microchip Pet Door is ideal for mounting in single or double-glazed windows. If
you need to have a hole cut in a window, please ask a qualified glazier to do it, as cutting glass
is a skilled job. If you need to get a hole cut in your window a circular hole with a diameter of
300mm (11 13/16") is the ideal size. A mounting adaptor (Product Code: GMA101) is available
to complete an installation in glass, and is suitable for covering holes from 294mm (11 9/16")
to 320mm (12 5/8") in diameter, see Figure 10.
For details of where to purchase this adaptor see our website www.surepetcare.com.
If you have a double-glazed window you will need to get a replacement unit manufactured with
the hole cut in it. If possible you should request the use of a non-metallic spacer bar.
Once your glass has been cut and installed in the door or window you are ready to complete
the install.
1.
A circular hole 300mm in diameter is required to accommodate the tunnel. See Figure 11.
2.
We recommend running a bead of 'All Weather Sealant' around the edge of the mounting
adaptor for both sides of the glass, see Figure 12. The sealant will help secure the pet
door in place after installation, particularly with larger hole sizes, and also help prevent
moisture getting in from outside. This type of sealant can be purchased from a glazing
company and most DIY stores.
3.
Slide one of the mounting adaptor rings over the main assembly.
4.
From inside the house slide the tunnel of the main assembly through the hole in the glass.
From outside the assembly should look like that of Figure 13.
5.
From outside the house mount the second part of the mounting adaptor and then the
external frame, see Figure 14 and 15.
6.
Screw the two halves together as in Figure 16. If mounting in a single pane use the
shortest of the three pairs of screws. A double glazed panel may require the mid-sized
screw, depending on its thickness. Check the assembly is centred with the circular hole
before fully tightening the screws.
7.
Align the white screw caps with the slot pointing outwards and then push firmly into place.