EN
TWINDOSE 40 EVO PLUS 100 mS
3
CONNECTION DIAGRAM
Signal
Power Supply
Charge trigger
Rinse trigger
Wash trigger
Alarm output
Pressure switch
Detergent level
Rinse aid level
NOT USED
Temperature probe
Conductivity probe
Inductive probe
Console interface
External memory
Keypad
Solenoid valve piloting
Out 1
Out 2
3.1 ELECTRICAL CONNECTIONS
CAUTION: TWINDOSE 40 EVO PLUS provide high voltage at the transformer connection. Always
switch off the power supply before doing any maintenance work on the appliance.
Use a multimeter to check all the electrical connections on the TWINDOSE 40 PLUS. Applying the
incorrect voltage could permanently damage the appliance and such damage is not covered by the
guarantee. Do not connect to power supplies subject to widely fluctuating voltages and/or peak
currents. When forming any electrical connections, refer to the wiring diagram in this manual.
All wiring must be carried out in compliance with local regulations for electrical connections.
0000137202
CPU
Type of signal
VAC (24 or 115-230)
VAC (24 or 115-230)
VAC (24 or 115-230)
VAC (24 or 115-230)
Dry contact
Dry contact
Dry contact
Dry contact
PT100
VDC (0-5V)
VDC (0-5V)
VDC (0-5V)
VDC (0-5V)
VDC (0-5V)
VDC (0-5V)
VAC (24 o 115-230)
VAC (24 o 115-230)
Rev. 1.0
ALIMENTATO RE
POWER UNIT
OUT 1
25 26
L N
Connector
LN (1-2)
CHARGE (3-4)
RINSE (5-6)
WASH (7-8)
ALARM OUT (9-10)
PRESSURE SWITCH (11-12)
DETER LEVEL (13-14)
RINSE LEVEL (15-16)
SANIT LEVEL (17-18)
TEMP PROBE (19-20)
COND PROBE (21-22)
COND PROBE (21-22-23-24)
CONSOLE
MEMORY
KEYPAD
SOL VALVE
LN (25-26)
LN (27-28)
1 2
OUT 2
27 28
L N
L N
Type
INPUT
INPUT
INPUT
INPUT
OUTPUT
INPUT
INPUT
INPUT
NOT USED
INPUT
INPUT
INPUT
INLET-OUTLET
INLET-OUTLET
INPUT
OUTPUT
OUTPUT
OUTPUT