DISPLAY AND PRELIMINARY OPERATING MODES
6.1
DISPLAY MODE
Change display mode
Press the key
to change the display mode of the information that is displayed according to the
following diagram:
*
DET
12.0g/L 15.0g/m
01.01.2008
22:35
COUNTERS
23L
In the display mode of the concentrations set for calibrated operation, the value is shown in grams/minute for
rinse aid or, if the Rinse Flow rate (conveyor) or Rinse Volume (single-tank) value is programmed, the
concentration in grams/litre is displayed.
In the conductivity display mode if the system cannot read a valid value from the probe it will show 0.2 mS
flashing (value too low) or the message "Out of scale" (value too high).
In the temperature display mode flashing values indicate that the system is using the default of 25°C.
6.2
AUTOMATIC- MANUAL MODE
If the system is set in manual mode, choose the program to perform using the P1 and P2 keys:
0000137202
System
Standby
RINS
15L
3L
Temperature
25°C
Prog1 Activation
In progress...
Rev. 1.0
Prog1
Manual
DET
BRIL
ON
OFF
SP=99SkU
CD=86SkU
77°F
Prog2 Activation
In progress...
NORMAL
99.9mS
91.9mS
*
Only in calibrated mode