Herunterladen Inhalt Inhalt Diese Seite drucken

seko TWINDOSE 40 EVO PLUS Installationshandbuch Seite 20

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
EN
TWINDOSE 40 EVO PLUS 100 mS
9.3.3
ALARM SUBMENUS
ALARMS
Buzzer
Active
<-
Det Alarm
Not active
<-
Rinse Aid Alarm
Active
<-
Stop Level Alarm
Not active
<-
OFA
999 sec
<-
After a time of two OFA, system crashes and freezes the relay outputs.
9.3.4
COUNTER SUBMENU
MENU
COUNTERS
Det Counter
9999 Ore
<-
Rinse Counter
9999 Litri
<-
Alarm duration
99 min
<-
If you set a counters alarm value for each pump, the system will indicate if the product has finished and after
the set number of minutes it will block subsequent dosing of the product.
To reset the pump operation it is necessary to add more product and insert the new quantity.
To disable the counters alarm management, just set the value 0.
0000137202
You can activate or deactivate the buzzer that rings when an alarm is set off.
You can activate or deactivate the detergent level alarm; if active this alarm only
works if a level probe is connected to the system which monitors the minimum
quantity and signals the addition of product.
You can activate or deactivate the rinse aid level alarm; if active this alarm only
works if a level probe is connected to the system which monitors the minimum
quantity and signals the addition of product.
This item is only present if at least one level alarm is active; if it gets activated, in the
presence of a level alarm, the system blocks the pump in question, otherwise also in
the presence of a level alarm the system continues to work, showing the alarm on the
display.
This item is only present if the conductivity is active; you can set a time for which if
the system does not reach the SetPoint an alarm is triggered.
You can set an initial value for a counter for the detergent product expressed in hours;
this counter is used to monitor the consumption of the product and to indicate if the
product has finished.
You can set an initial value for a counter for the rinse product expressed in hours;
this counter is used to monitor the consumption of the product and to indicate if
the product has finished.
You can set a valid time for all the counters with which, even if the counter goes to 0
each pump will continue to dose for the set time. This time refers to the operation of
the pump and the value entered is the same but is independent for each individual
pump.
Rev. 1.0
19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis