TWINDOSE 40 EVO PLUS 100 mS
that time has passed (becoming first charge) the pump doses for the "First Det. Charge" time. If during
dosing the TR trigger becomes inactive the pump stops.
The RINSE pump starts immediately and performs the dosing based on the programming (speed, time,
on/off) for a maximum programmed "Rinse Duration" time. If during dosing the trigger becomes inactive the
pump stops.
8.1.3
SINGLE-TANK MODE WITH ACTIVE CONDUCTIVITY WITH 2 SOLENOID VALVES
CHARGE TRIGGER: After the programmed Filter Signal time, the Det pump doses for the "First Det.
Charge" time programmed. If during dosing the trigger becomes inactive the pump stops.
RINSE TRIGGER: The RINSE pump starts immediately and performs the dosing based on the programming
(speed, time, on/off) for a maximum programmed "Rinse Duration" time. If during dosing the trigger becomes
inactive the pump stops.
WASH TRIGGER: The DET pump is activated based on the SetPoint programmed and the dosing speed is
proportional to the difference between SetPoint and conductivity read. During dosing the OFA alarm is
managed.
8.1.4
SINGLE-TANK MODE WITH INACTIVE CONDUCTIVITY WITH 2 SOLENOID VALVES
CHARGE TRIGGER: After the programmed Filter Signal time, the Det pump doses for the "First Det.
Charge" time programmed. If during dosing the trigger becomes inactive the pump stops.
RINSE TRIGGER: The DET pump starts to dose immediately in the programmed mode (Time, Reset, Reset
Speed or On/Off Reset). If during dosing the trigger becomes inactive the pump stops.
The RINSE pump starts immediately and performs the dosing based on the programming (speed, time,
on/off) for a maximum programmed "Rinse Duration" time. If during dosing the trigger becomes inactive the
pump stops.
8.2
"STANDARD" MODE FOR CONVEYOR DISHWASHING MACHINE
8.2.1
CONVEYOR MODE WITH ACTIVE CONDUCTIVITY WITH 2 SOLENOID VALVES
CHARGE TRIGGER: After the programmed Filter Signal time, the Det pump doses for the "First Det.
Charge" time programmed. If during dosing the trigger becomes inactive the pump stops.
RINSE TRIGGER: The RINSE pumps starts immediately and performs the dosing based on the
programming (speed, time, on/off) until the TR trigger is active and for a maximum of the "Rinse Duration"
time programmed.
WASH TRIGGER: The DET pump is activated based on the SetPoint programmed and the dosing speed is
proportional to the difference between SetPoint and conductivity read. During dosing the OFA alarm is
managed.
8.2.2
CONVEYOR MODE WITH INACTIVE CONDUCTIVITY WITH 2 SOLENOID VALVES
CHARGE TRIGGER: After the programmed Filter Signal time, the Det pump doses for the "First Det.
Charge" time programmed. If during dosing the trigger becomes inactive the pump stops.
RINSE TRIGGER: If the dosing has been programmed in time the DET pump starts to dose immediately for
the "Reset Time" programmed; after a time equal to "Drums time" - "Reset time" the dosing is repeated. If
the dosing has been programmed in speed the pump immediately doses at the programmed speed. If the
On-Off dosing has been programmed the pump immediately doses with On and Off programmed. In all
modes if during dosing the TR trigger becomes inactive the pump stops.
The RINSE pumps starts immediately and performs the dosing based on the programming (speed, time,
on/off) until the TR trigger is active and for a maximum of the "Rinse Duration" time programmed.