Herunterladen Inhalt Inhalt Diese Seite drucken

Components And Accessories; Maintenance And Care; Help In Case Of Malfunctions - G-U ELTRAL VA25 Montage- Und Betriebsanleitung

Verriegelungsantrieb
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.6

Components and accessories

Only adapted for ELTRAL K25-24V and ELTRAL K60-24V
Locking drive ELTRAL VA25
GU-No. K-17724-00-0-8
Testing and setting apparatus
GU-No. K-17736-00-0-00
Security stay Euro-Solid
Sash high
GU-No.
270 - 350 mm
6-27995-01-0-1
351 - 500 mm
6-27995-03-0-1
501 - 800 mm
6-27995-04-0-1
801-1500 mm
6-27995-05-0-1
The installation of the security stay may require a profile-related base plate. See catalogue.
Fastening kits vary depending on installation method, profile system and profile material
2.7

Maintenance and care

To ensure a problem-free operation, you must perform the following jobs after every 1.000 opening
cycles, however, at least once a year:
Check all screws to ensure they are tight and retighten them if necessary.
Check if the window sash is seated perfectly in the window frame. Adjust fixings if necessary.
Check all parts for damage and wear. Replace parts where necessary.
Never use acidic or basic cleaning agents. Do not immerse the appliance in water.
Do not try to repair the drive yourself in case of failure. Do not remove the casing or other parts.
In case of signs of damage to the appliance contact the manufacturer. Only spare parts supplied
by the manufacturer may be used for repair.
If a defect appears with one as concealed built-in locking drive so can be opened the window by
an emergency unlock (see section „ 2.8 help in case of malfunctions")
2.8

Help in case of malfunctions

The metal building company or end-user cannot repair a faulty motor properly, therefore this is not
permitted. Repairs may only be carried out in the factory. If you open the motor or tamper with it, the
warranty becomes null and void.
Therefore you should replace a faulty motor and have it repaired.
If the motor is immobilised, check whether the load cutout has been activated.
In case any problems arise during installation or operation of the drive, please consult the following
table for possible help:
Problem
Drive not functioning
If the motor does not respond to actuation by switch/button, have the power supply checked by
a qualified person.
Emergency unlock of the engine with installation concealed in the profile
Before the installation of the locking drive a drilling must be introduced in the profile and be closed
again with a suitable cover, so that no dirt can penetrate into the engine.
To the emergency unlock of the locking drive remove the cover and break through the self adhe-
sive circle. With a cross-recessed screwdriver (Philips size 3) access the bevel wheel in the engine.
According to locking position the screwdriver must be turned in or against the hand sense.
21
22
Possible cause
Solution
• Mains adapter without current
• Check state of fault current
supply
protection switch or safety
switch
• Check all electrical connec-
• Connecting cable unplugged
tions of drive
or wire(s) loose
• Exchange mains adapter
• Mains adapter not providing
the rated voltage (24V)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis