ER13 : the inside temperature is lower than the limit
value;
ER14 : the inside temperature is higher than the limit
value.
It should be noted that malfunction signals (ER01, ER02
and ER03 codes) caused by critical appliance
malfunctions will cause the appliance to stop working
until the problem has been resolved. In this case, the
alarm will sound for 30 seconds. After this time it will
stop and an error message will remain on the display. In
other cases, once a problem has been signalled, the
appliance will go on working at V min with the by-pass
valve closed over-riding signals from sensors. The alarm
will sound for 5 seconds. After this time it will stop and
an error message will remain on the display. In these
circumstances, the user will not be able to change the
operating mode(e.g. MAN or SUMMER). Pressing the
RESET buttons following the display of a malfunction
code will shut off the acoustic alarm; The display on the
remote control unit however will continue to show the
malfunction signal until the problem has been resolved.
Reset
To reset equipment status (if the remote control
disabling procedure has not been carried out), press the
following keys in sequence:
DISPLAY --> "-" (Minus) --> DISPLAY --> "+" (Plus)
After the RESET, the appliance resumes operation in
AUTO mode as per the initial standard parameters.
Any error messages is no longer displayed (of course if
the problem causing the malfunction has been solved).
Likewise, in the event of a power failure, when power is
restored, the appliance will return to working in AUTO
mode using its initial standard parameter settings.
34

Fuse

The appliance has 2 A fuse fitted in series with the
power supply cable. (fig.29)
29
29
In the event of repeated fuse failures, the appliance
should be checked by a trained electrician.

Maintenance/Cleaning

Filters
The periodical cleaning and maintenance of the filters is
left to the user. The filters must be kept clean to ensure
a correct and healthy operation of the appliance.
It is advisable to replace the filters once a year. To
access the filters follow the instructions below:
switch off the appliance (ON/OFF button);
wait 15 seconds;
disconnect the appliance from the mains power
supply;
Extract the filters from the appliance (fig.30,31,32)