d) Do not restart the cutting operation in the
workpiece. Let the wheel reach full speed
and carefully re-enter the cut. The wheel
may bind, walk up or kickback if the power tool
is restarted in the workpiece.
e) Support panels or any oversized workpiece
to minimize the risk of wheel pinching and
kickback. Large workpieces tend to sag under
their own weight. Supports must be placed
under the workpiece near the line of cut and
near the edge of the workpiece on both sides
of the wheel.
f) Use extra caution when making a "pocket
cut" into existing walls or other blind areas.
The protruding wheel may cut gas or water
pipes, electrical wiring or objects that can
cause kickback.

Electrical safety

When using electric machines always observe the
safety regulations applicable in your country to
reduce the risk of fire, electric shock and personal
injury. Read the following safety instructions and
also the enclosed safety instructions.
Always check that the voltage of the
power supply corresponds to the voltage
on the rating plate label.
Class II machine - Double insulation - You
don't need any earthed plug.
If operating a power tool in a damp location is
unavoidable, use a residual current device (RCD)
protected supply. Use of an RCD reduces the risk
of electric shock.

2. MACHINE INFORMATION

Intended use
Your angle grinder has been designed for grinding
masonry and steel materials without the use of
water. For cutting, a special protection guard
must be used (not included)

Technical specifications

Mains voltage
Mains frequency
Power input
Rated speed
Wheel disc for grinding
Diameter
Bore
Thickness
Wheel disc for cutting
Diameter
Bore
Thickness
Spindle thread
Weight
Sound pressure (L
)
PA
Acoustic power (L
)
WA
Vibration "Surface grinding" a
h,AG
Vibration level
The vibration emission level stated in this instruction
manual has been measured in accordance with
a standardised test given in EN 60745; it may be
used to compare one tool with another and as a
preliminary assessment of exposure to vibration
when using the tool for the applications mentioned
• using the tool for different applications, or with
different or poorly maintained accessories,
may significantly increase the exposure level
• the times when the tool is switched off or when
it is running but not actually doing the job, may
significantly reduce the exposure level
Protect yourself against the effects of vibration by
maintaining the tool and its accessories, keeping
your hands warm, and organizing your work
patterns.
Description
The numbers in the text refer to the diagrams on
pages 2-4
AGM1096P
220-240 V~
50 Hz
1400W
10.500 /min
125 mm
22.2 mm
6 mm
125 mm
22.2 mm
3 mm
M14
3.9 kg
87.97 + 3 dB(A)
98.97 + 3 dB(A)
15.161 + 1.5 m/s
2