Herunterladen Inhalt Inhalt Diese Seite drucken

Limitations On Use; Approvals; Tested Personal Protective Equipment - Dräger CPS 7900 Gebrauchsanweisung

Schutzanzüge
Vorschau ausblenden Andere Handbücher für CPS 7900:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Description
2.2

Limitations on use

Certain chemicals are subject to restrictions regarding the
period of use depending on concentration, state of aggregation
and ambient conditions. For information on mechanical and
chemical resistance as well as on temperature resistance, see
"Resistance of the suit material" on page 36.
Avoid heat and open flames. The chemical protective suit is
not suitable for fire fighting. For operational temperatures, see
chap. 8 on page 36.
The chemical protective suit does not offer protection against
radiation of radioactive particles or radiation damage.
The chemical protective suit may not be used when it is
damaged or worn.
2.3

Approvals

The chemical protective suit is approved according to the
following standards and directives:
EN 943-1:2002 and EN 943-2:2002
89/686/EEC
EN 14126:2003:1a-ET-B
BS 8467:2006:category A
EN 1073-1:1998:IL:Class 4
(only Dräger CPS 7900 with ventilation unit)
EN 1073-2:2002:IL:Class 3
(only Dräger CPS 7900 without ventilation unit)
EN 14593-1:2005
(only Dräger CPS 7900 with ventilation unit)
NFPA 1991:2005
(only Dräger CPS 7900 with glove combination 3 (inside
Silvershield glove, covered with Butyl glove, outside K-mex
Gigant glove), socks and a cover of the suit valves made of
suit material
vfdb Directive 0801:2006-11
(only Dräger CPS 7900 without ventilation unit)
ISO 16 602:2007
SOLAS II-2, Reg. 19, consolidated edition 2004
NOTICE
i
i
The standards according to which the respective
chemical protective suit is approved are marked with a
dot on the rating plate.
The following warranty provisions apply to chemical protective
suits which are approved according to NFPA 1991:2005:
If not otherwise agreed between Dräger and the customer, the
following applies for material or manufacturing errors: The
customer contacts the company where he purchased the
product (the "seller"). The warranty provisions which have
been agreed between the customers and seller apply. The
product has to be used in the same way as described in the
Instructions for Use. When the product is used differently, this
may mean that the warranty claims not valid.
26
2.4

Tested personal protective equipment

CAUTION
!
The following combinations of protective equipment
have been tested and approved by Dräger.
Other combinations are not tested and approved by
Dräger. For non-Dräger approved combinations, the
operator must independently determine whether such
combination is appropriate.
2.4.1
Facepieces
Full facepieces Dräger FPS 7000 RA/PE/P/ESA
Full facepieces Panorama Nova RA/PE/P/ESA
Full facepieces f2 PA-RA/PE
Mask/helmet combinations Dräger FPS 7000 H61/H62
Mask/helmet combinations Panorama Nova S-RA/Supra,
Panorama Nova S-PE/Supra and Panorama Nova S-HE-
EPDM-PC-RA
Mask/helmet combinations f2 S-PA-PE/Supra
2.4.2
Self-contained breathing apparatus
PA 80/90 UP
PA 94 UP
PA 94 D plus
PSS 100D
1
PSS 100
1
PSS 3000
1
PAS 3000
1
PSS 5000
1
PSS 7000
2.4.3
Lung demand valves
all lung demand valves of the PSS series
2.4.4
Safety helmets
Dräger HPS 4100
Dräger HPS 4300
Dräger HPS 6100
Dräger HPS 6200
Schuberth F110
Schuberth F210
Dräger F1S12
Dräger F1SA12
Heros I
Heros II
1
Also in combination with ASV and Y-piece while using an ASV
Dräger CPS 7900

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis