3. How to use
Value Description
Operation without load shedding
0
relay, factory setting
Operation with normal
1
load shedding relay
Operation with sensitive
2
load shedding relay
Brightness: Reduce the display brightness e.g. to safe energy. The brightness can be
set separately for operation screen and standby screen.
• Operation screen 5-100%
• Standby screen 0-100% (0% = display OFF)
The setting of the standby screen will be activated after one minute in standby mode.
Icon Size: Selection of "S" small or "L" large visualization The displays and symbols in
the main control are then displayed accordingly either smaller or larger.
Sound: Activate / deactivate operating sounds.
Note: Alarm signals and instruction sounds are not affected by this function.
Load Shedding: If further three-phase appliances are connected, a load shedding relay
designed for electronic instantaneous water heaters (CLAGE no. 82250) can be con-
nected to phase conductor L2. This relay ensures the operation of the water heater by
switching off other consumers until the end of heating operation.
Tap on or to set a value of 0, 1 or 2.
Operating mode 1 must be selected first, thus to check the correct operation of the
load shedding relay at low appliance output (35 degree celsius setpoint and low water
flow rate). Mode 2 must be selected if the load shedding relay flickers.
Flow Limit: Setting of flow rate limitation.
Setting options:
"OFF"
no flow rate limitation (motor valve deactivated)
"AUTO"
automatic adjustment, i.e. flow rate is limited in a way so that the selected
outlet temperature is reached
"ECO"
flow rate limitation to max. 8.0 l/min
e.g. "9.0" limitation to a freely selectable value between 4.5 and 25 l/min
Note: If the Eco function has been activated in the menu "Savings", the flow is
automatically set to "ECO". Changing the flow to a higher value than 8 l/min
deactivates the Eco function
Delete Statistics: Use this function to delete all previously collected statistical data.
Deleted statistical data cannot be restored.
Factory Settings: All factory settings can be recalled:
Note: All customised user profiles, and power and water prices entered, are
deleted. If a load shedding relay is connected, the correct value must be reset
under "Load shedding".

User

Up to eight users can enter their names with up to ten letters and select their own
profile image. This appears together with the first three letters of the name in the main
control.
In the main control, every user can set up and save his own desired temperatures for
the different applications.
By tapping on the symbol
23
you can delete a user profile.