Maintaining the BestWater System
En
Wait about 5 minutes, until the pre-
filters have filled with water and
been rinsed. Open the stopcock on
the reservoir tank.
The system is now producing pu-
rified water that flows through the
disinfection module and dissolves
the hydrogen peroxide (H
O
2
2
the disinfection module. When drai-
ning later, the disinfectant will disin-
fect all hoses that the purified water
passes through.
After approx. 40 min. you must
drain all of the water through the
faucet. Wait long enough that the
water starts to trickle slowly out of
the faucet.
56
Now you can remove the disinfec-
tion module. While removing it, pu-
rified water that is currently being
processed may pour out.
Insert the plastic hose back into
the stopcock of the stored pressure
tank.
) within
Fill the reservoir again and let the
water drain completely through the
faucet one more time.
Your annual filter change is now
complete and you can operate the
unit normally again.
Checking air pressure in the
stored pressure tank
The stored pressure tank of the
Jungbrunnen 22-00 ULTIMATE is
equipped with a natural rubber
membrane that helps push out the
drinking water from the reservoir
during extraction.
In order to check the air pressure
in the stored pressure tank, and to
adjust it if needed, refer to the fol-
lowing images for assistance and
follow these steps:
Close the stopcock on the stored
pressure tank and remove the hose
from the stopcock.
Remove the stored pressure tank to
set the air pressure.
Unscrew the cap from the bottom of
the stored pressure tank. Located
beneath this is the valve for setting
the air pressure.
An air pump with a built-in mano-
Maintaining the BestWater System
meter or a compressor is ideal for
monitoring/setting the air pressu-
re in the stored pressure tank. It is
best to lay the tank on the foot on
its side. Set the air pump or com-
pressor onto the valve.
Pump the tank to a pressure of 0.3 -
0.5 bar. The air pressure in the tank
is now set.
The air pressure in the stored pres-
sure tank should be checked or re-
set, when empty, every 2 - 3 years.
Set the stored pressure tank back
in its place, and reinsert the plastic
hose into the stopcock of the stored
pressure tank and open the stop-
cock on the stored pressure tank.
Disinfecting the faucet
The faucet must be cleaned regular-
ly so that bacteria do not build up
inside it. We recommend disinfec-
ting the faucet every 2 months. Use
these images for assistance when
disinfecting the faucet, and follow
these steps:
En
57