Troubleshooting
En
Problem
Leakages
Water filtration system
incorrectly assembled
Connecting piece loose or
damaged
Permeate pump is leaking
Permeate pump
Water pressure too low
working constantly
Pressuriser damaged
Incorrectly aligned
50
Cause
Solution
Carefully follow the
steps in the assembly
instructions.
Seal and/or replace
the connecting piece.
Realign hose connec-
tion or replace pump.
See point 1.
Replace the pressu-
riser.
Align the pump ver-
tically (water exits
facing up – see mar-
king).
The water filters must be regularly
maintained and replaced (see Terms
of Warranty) in order for your water
filtration system to function reliably
and produce high-quality water over
a long period of time. The pre-filters
are the first level before the memb-
rane, which they protect in a special
way. Let a professional, authorised
installer (e.g. gas-water installer)
who has the proper tools (such as
an air pressure gauge) be present
during the work required to main-
tain your water filtration system
to provide you with instructions.
The general condition of your unit
should be assessed during the an-
nual maintenance, and the following
steps must be followed:
Check the hose connections (re-
place if necessary)
Check the connectors (replace if
necessary)
Measure the air pressure in the
storage tank (set if necessary)
Check the rubber seals (replace if
necessary)
Change and disinfect the filter
(see below)
Let these images assist you while
you follow these steps.
Semiannual filter replacement
Use these images to help you with
your semiannual filter change and
replacing the 20 µm pre-filter, and
follow these steps using the images
below:
Maintaining the BestWater System
When you start maintenance, you
must stop the flow of water to the
device. Please close the corner valve
and turn on the faucet in order to
empty out the reservoir.
Open the front hatch of the BestWa-
ter system. Use the star screwdriver
to unscrew the individual screws on
both sides of the front hatch and re-
move the hatch from the system.