Filling the pump

Fill up the house water dispenser every
time before you start using it. This will en-
sure an immediate start. Running dry will
destroy the pump.
Use a wrench (SW17) to unscrew the
B
filler screw (
19) at the back of the
home water dispenser.
Fill in water up to the mark and screw
in the filler screw (
Mind to also fill the suction hose with
water.

Operational start-up

Check that the electrical connec-
tion is 230V ~50Hz
Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 10 A). In-
sert the pump plug into the plug
socket and the pump is ready
for operation.
Make sure that moisture or wa-
ter never come in contact with
the mains connection.
There is a risk of electrocution.

Starting the unit

Connect the power cable of the auto-
A
matic switch (
ply.
When you connect the appliance
to the mains, all lamps will first of
all light up.
Set the On/Off switch (
the unit.
The "Power On" indicator (
light up to indicate that the unit is
ready to operate.
B
19).
2) to the power sup-
A
5) to turn on
A
12) will
The "Pump On" indicator (
you that the pump is working.
The "Alarm" indicator (
when the appliance turns itself off au-
tomatically.

Restarting the appliance

Following automatic switch-off of the ap-
pliance, press the restart switch (
If restarting the appliance fails several
times, fill up the pump with new water.
Maintenance
Instructions
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only original
parts.
Pull out the power plug before every
maintenance operation. There is a
risk of electrocution or of injury from
moving parts.

General cleaning instructions

In case the unit clogs up, remove the
suction and pressure hoses. Remove the
A
automatic switch (
wash out the obstructing particle.
Any measures above and beyond these,
particularly opening the equipment, are
to be carried out by an electrician. In the
case of repairs, always contact our serv-
ice centre.
GB