3.2

3.2 Switch Box

The switch box is located in the heat pump. It can be accessed
by removing the lower front cover.
The switch box contains the supply connection terminals, as well
the power contactor, soft starter unit and heat pump controller.
Both supply connection cables are installed ready for use.

3.3 Accessories Pack

Contents:
2
Sealing rings for duct connection
3
1" connecting hoses
3
1" double nipples
6
1" flat gaskets
1
1" sealing plug
1
Hose nozzle for filling and drain cock
2
Fixing brackets
2
10 mm dowels
2
8 x 80 screws
4
M4 x 8 screws
1
External sensor
2
6 mm dowels
2
4.5 x 50 screws
E-4
4

Transport

ATTENTION!
When transporting the heat pump, care must be taken to ensure that it is
not tilted more than 45° (in any direction).
Use a wooden pallet for transporting the heat pump to the final in-
stallation location. The basic device can be transported with a lift
truck, hand truck or by means of 3/4" pipes fed through the holes
in the base plate or frame.
ATTENTION!
The heat pump and the wooden pallet are only joined by the packing film.
Before using the holes in the frame, it is advisable to remove
each of the side panel assemblies. This is done by loosening
each of the two screws at the base and then withdrawing the
panels by unhooking them from above. Rehang the panels by
gently pushing them in an upwards direction.
Opening the cover