Herunterladen Inhalt Inhalt Diese Seite drucken

Hitachi WR 36DA Bedienungsanleitung Seite 11

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
(2) Regarding the temperatures and charging time of the rechargeable battery
The temperatures and charging time will become as shown in Table 2.
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
Charging voltage
USB
Charging current
NOTE
The recharging time may vary according to the ambient
temperature and power source voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.5 seconds. Does not light for
Blinks
1 second. (off for 1 second)
(BLUE)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(BLUE)
Lights
Lights continuously
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light for
Blinks
0.3 seconds. (off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
(PURPLE)
(Intermittent buzzer sound: about 2
seconds)
Charger
V
14.4
BSL14xx series
(4 cells)
BSL1415S : 15
BSL1415 : 15
BSL1415X : 15
min.
BSL1420 : 20
BSL1425 : 25
BSL1430C : 30
V
A
Table 1
Table 2
UC18YSL3
Li-ion
-10°C – 50°C
BSL18xx series
(8 cells)
(5 cells)
BSL1815S : 15
BSL1430 : 20
BSL1815 : 15
BSL1440 : 26
BSL1815X : 15
BSL1450 : 32
BSL1820 : 20
BSL1460 : 38
BSL1825 : 25
BSL1830C : 30
5
2
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries and
batteries that have not been used for an extended period
is not activated, the electric discharge might be low when
using them the fi rst and second time. This is a temporary
phenomenon, and normal time required for recharging
will be restored by recharging the batteries 2 – 3 times.
11
Plugged into power source
Battery capacity at less than 50%
Battery capacity at less than 80%
Battery capacity at more than 80%
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger
18
Multi volt
(10 cells)
(10 cells)
BSL1830 : 20
BSL1840 : 26
BSL36A18 : 32
BSL1850 : 32
BSL1860 : 38
English
series

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wr 36db

Inhaltsverzeichnis