Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Protective Measures - Oase PondoVac Premium Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für PondoVac Premium:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
4

Installation and connection

B, C
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries due to operation of electrical units or installations in
or near ponds/pools.

Protective measures:

Set up the unit at least 2 m away from the pond/pool.
Ensure that the ground under the unit is firm and horizontal so that the unit cannot tip over.
Apply the parking brake to prevent the unit from moving during operation.
Adhere to national and regional regulations.
Only set up and operate the unit in a position that is higher than the level of the water. Possible
consequences if the unit is operated in a position that is lower than the level of the water:
Water will automatically flow into the tank. This will negatively affect the suction mode.
When the unit is switched off, water will automatically flow through the tank. The pond/pool will be
emptied.
Transport and installation of the unit
Transport the unit on its own wheels.
Do not lift the unit by its handle.
The unit weighs more than 40 kg. Use a suitable carrying aid for lifting the unit.
The following conditions must be met:
Allow the dirty water to drain out into a drain or far enough away from the pond to ensure that it cannot
flow back into the pond.
Completely unwind the power and extension cable.
Ensure that the cables are not bundled together or coiled up.
Connect the discharge hose and floating suction hose as well as the Oase nozzles.
Recommendation: Use a bend-resistant discharge hose for the first 10 metres. A bend-resistant
hose allows unrestricted flow of the dirty water.