5.2

Suction mode

Attention! Dangerous electrical voltage!
Possible consequences: Death or severe injury.
Protective measures: Prior to starting up the unit, switch off the mains voltage of all units located in the
water.
Note! The electronics will be destroyed .
Never operate the unit without the filter element!
Plunge the extension wand with floating suction hose and nozzle into the water and vacuum the floor
of the pond/pool.
The green LEDs on the operating panel light up/flicker to indicate the water level in the tank.
• ... ••: The discharge pump switches on automatically and pumps the dirty water out of the tank.
•• ... •••: The maximum water level is reached. Excessive dirt has collected at the bottom of the
tank, the discharge pump can no longer pump out the dirty water.
The vacuum can be manually switched off with "Vac OFF" when required.
The discharge pump can be manually switched on with "Pump ON" when required.
Recommendation: Empty the unit to reduced the weight. This will make it easier to move the unit.
In order to switch off the vacuum during discharge press "Pump ON" and "Vac OFF" simultaneously.
Empty the tank via the discharge pump before carrying out cleaning and maintenance measures.
Recommendation: Vacuum up clean water and empty the tank again. This will wash out the dirt
particles.
Clean the unit after each use. (→ Cleaning and maintenance)