Installation and connection

NOTE
If you are using the pump as a booster pump, ensure that the max. internal pressure of 6 bar on
the pressure side is not exceeded.
The pump pressure is added to the pre-pressure.
Example: Pre-pressure = 1 bar, max. pressure of the pump = 4.5 bar, total pressure = 5.5 bar.
To reduce pump noise, connect the pump to the pipework via flexible, pressure-resistant
hose lines for fixed installation.
Equip the suction line with a pre-filter and a non-return or foot valve. In addition, fasten the
suction hose (e.g. tying it to a stake) to take its weight off the pump.
 Install the pump in a horizontal and stable position in a dry place.
– For permanent installation of the pump, ensure that a sufficiently large collecting basin can
be positioned underneath the discharge screw for emptying the pump.
 If possible, install the pump in a higher position than the container/reservoir from which the
water is to be pumped. If this is not possible, a pressure-proof valve must be fitted between
the pump and the suction hose.
 Only use vacuum-proof pressure hoses on the pressure and suction side.
 Screw a suction and pressure hose with 25.0 mm internal diameter (1") onto the connections.