For your safety

Strictly follow the Instructions for Use
Any use of the device requires full understanding and strict observation of these
Instructions for Use. The device is to be used for the purposes specified here only.
Maintenance
The maintenance intervals and measures specified in the Technical Manual
well as the specifications in the Instructions for Use/data sheets of the
® 2)
DrägerSensor
sensors used must be carefully observed.
Device maintenance must only be carried out by trained service personnel.
Accessories
Only the accessories specified in the order list in the Technical Manual
used.
Safe coupling with electrical devices
Electrical connection with devices not given in the Instructions for Use only
following consultation with the manufacturers or a specialist.
Use in areas subject to explosion hazards
Devices or components for use in explosion-hazard areas which have been tested
and approved according to national, European or international Explosion
Protection Regulations may only be used under the conditions specified in the
approval and with consideration of the relevant legal regulations. No modifications
to the equipment, devices or components are permitted. The use of faulty or
incomplete parts is forbidden. The relevant regulations must be observed at all
times when carrying out repairs on these devices or components. Device
maintenance must only be carried out by trained service personnel in line with
Dräger maintenance instructions.
Safety symbols used in these Instructions for Use
These Instructions for Use use a number of warnings for risks and hazards that
which will occur when using the device. These warnings contain signal words
which will alert you to the degree of hazard you may encounter. These signal
words and the associated hazards are as follows:
1) The Technical Manual and Instructions for Use/data sheets for the sensors used and the Dräger
PC software CC-Vision for Dräger X-am 5000 can be downloaded on the product page for the
X-am 5000 at the following Internet address: www.draeger.com
See also the enclosed Instructions for Use and data sheets for the sensors used.
®
2) DrägerSensor
is a registered trademark of Dräger.
Death or serious physical injury may occur due to a potentially hazardous
situation if the relevant safety precautions have not been taken.
Physical injury or damage to property may occur due to a potentially hazardous
1)
as
situation if the relevant safety precautions have not been taken. Can also be
used to warn against careless actions.
Additional information for the use of the device.
1)
maybe

Intended use

Portable gas detection instrument for the continuous monitoring of the
concentration of several gases in the ambient air within the working area and in
explosion-hazard areas.
Independent measurement of up to five gases, in accordance with the installed
Dräger sensors.
Areas subject to explosion hazards, classified by zones
The instrument is intended for use in explosion-hazard areas or mines, in which
firedamp classified by zone 0, zone 1 or zone 2 may occur. It is intended for
use within a temperature range of –20 °C to +50 °C, and for areas in which
gases of explosion groups IIA, IIB or IIC and temperature class T3 or T4
(depending on the batteries and rechargeable battery) may be present.
For zone 0, the temperature class is limited to T3.
If used in mines, the instrument is only to be used in areas known to have a low
risk of mechanical impact.
Areas subject to explosion hazards, classified by divisions.
The instrument is intended for use in explosion-hazard areas or mines, in which
firedamp classified by Class I&II, Div. 1 or Div. 2 may occur.
It is intended for use within a temperature range of –20 °C to +50 °C, and for areas
in which gases or dusts of groups A, B, C, D or E, F, G, and temperature class T3
or T4 (depending on the batteries and rechargeable battery) may be present.
WARNING
CAUTION