Herunterladen Inhalt Inhalt Diese Seite drucken

Start-Up And Operation Of Aap102 - NovoPress AXI102 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für AXI102:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AXI102/AAP102
EN
8.2
Expanding operation (Fig. 7)
1.
Check that the nominal width of the pipe matches the nominal width of the expander head.
2.
Check that the pipe and expander head are from the same system manufacturer.
3.
Slide the pipe into the expander head as far as the stop.
4.
Press the start button and hold it until the pipe has been expanded.
9

Start-up and operation of AAP102

9.1
Preparing AAP102
1.
The guide rod must be clean and greased.
If necessary, clean and lubricate the guide rod.
2.
Press the pin into the bolt and keep it pressed (1). (Fig. 8).
Pull the bolt out completely (2).
Release the pin.
3.
Push the pusher adapter with inscription 1 onto the guide rod in the direction of the arrow
(Fig. 9).
Information!
For product number: 45200; 45222; 45250:
Grease the expander cone
• Screw the expander head onto the expander and tighten by hand.
• Insert the battery.
CAUTION!
Danger of crushing!
There is a risk of crushed fingers and hands during the expanding process.
Therefore:
– Keep body parts and foreign objects away from the operating zone during the
expansion operation.
– Do not perform dry runs without expanding a pipe.
– Do not operate the device without the expander head.
Information!
Before an expanding process, observe the system manufacturer's instructions.
CAUTION!
Damage to pusher tool and pusher adaptors
Pressing operations using a system from a manufacturer for which the pusher tool and
pusher adaptors have not been designed may result in damage to the pusher tool and
pusher adaptors.
Therefore:
– Make sure that the system is press-fitted using the pusher tool and pusher adapters
from the system manufacturer.