Herunterladen Diese Seite drucken

L&W Compressors LW 160 E Handbuch Seite 5

Vorschau ausblenden Andere Handbücher für LW 160 E:

Werbung

Filling process
Fill only air tanks which are:
suitable for final pressure and hydro static tested (check last testing date).
- LW 160 E:
 Close filling valve
 Close drain valves of water separators
 Start compressor by switch
 Check direction of rotation
 Run compressor to max. pressure and check final savety valve
 Connect tank to compressor. Filling valve and tank are still closed
 Slowly open filling valve
 Carefully open tank valve
 Fill tank to desired pressure
 First close tank valve
 Close filling valve
 Release pressure between tank and filling valve by rotating the vent screw
A hissing sound can be heard
 Disconnect tank from compressor
 Turn off compressor by switch
- LW 190 B:
 Close filling valve
 Open drain valves of water separators
 Open fuel tank valve on Honda engine
 Adjust choke and throttle on Honda engine
 Turn switch to position 1 on Honda engine
 Start Honda engine
 Close drain valves of water separators
 Run compressor to max. pressure and check final savety valve
 Connect tank to compressor. Filling valve and tank are still closed
 Slowly open filling valve
 Carefully open tank valve
 Fill tank to desired pressure
 First close tank valve
 Close filling valve
 Release pressure between tank and filling valve by rotating the vent screw
A hissing sound can be heard
 Disconnect tank from compressor
 Turn off compressor by switch on Honda engine (position 0)
5

Werbung

loading

Diese Anleitung auch für:

Lw 190 b