Herunterladen Diese Seite drucken
Vorschau ausblenden Andere Handbücher für LW 160 E:

Werbung

I N S T R U C T I O N M A N U A L
LW 160 E
&
LW 190 B
Lenhardt & Wagner GmbH
Im Taubenfang 4
D-64653 Lorsch
Germany
Tel.: + 49 62 51 – 10 74 0
Fax: + 49 62 51 – 10 74 14
E-mail: info@lenhardt-wagner.de
1

Werbung

loading

Inhaltszusammenfassung für L&W Compressors LW 160 E

  • Seite 1 I N S T R U C T I O N M A N U A L LW 160 E & LW 190 B Lenhardt & Wagner GmbH Im Taubenfang 4 D-64653 Lorsch Germany Tel.: + 49 62 51 – 10 74 0 Fax: + 49 62 51 –...
  • Seite 2 Number of cylinders  Cylinder bores 72 / 28 / 13 mm Stroke 39 mm Motor LW 160 E: 4 kW; 380 V; 50 Hz Engine LW 190 B: Honda GX 270; 4-stroke; 6 kW Oil capacity of compressor 0.85 litre Dimensions...
  • Seite 3 General Notice This operation manual contains the operating and maintenance procedures necessary to safely run your L&W compressor. We strongly recommend that you read this manual thoroughly prior to operation and follow all the safety precautions precisely. Damage resulting from any deviation from these instructions is excluded from warranty and liability for this product.
  • Seite 4  Filling-hoses must be in perfect condition; special attention should be paid to the connecting fittings  On units with electric motor (LW 160 E) disconnect the power-cable prior to any work  Make sure no person is within one meter of the drain-hoses before draining the condensate ...
  • Seite 5 Filling process Fill only air tanks which are: suitable for final pressure and hydro static tested (check last testing date). - LW 160 E:  Close filling valve  Close drain valves of water separators  Start compressor by switch ...
  • Seite 6 Intake filter A micro filter cartridge is used as an air intake filter. The filter cartridge has to be checked regulary and should be replaced if necessary - at least once a year. A dirty contaminated filter restricts the airflow, reduces the compressor’s capacity and causes overheating.
  • Seite 7 Changing the mole carbon cartridge The mole carbon cartridge lasts for about 20 (LW 160 E) / 17 hours (LW 190 B) at an average humidity and at 25 degree centigrate. At 30 degree centigrate plus and high humidity, its life is reduced to 11 (10) hours. The cartridges are packed airtight.We recommend that they should be opened...
  • Seite 8 If pressure remains in the housing, it is almost impossible to open the filter housing cap. Pull out used filter cartridge and replaced it by a new one. Make sure O-ring is in place and in useable condition. Fit spring on top of filter.
  • Seite 9 Warranty Six Months Limited Warranty Important: For warranty claims this Warranty Registration form must be presented L&W compressors are warranted against defects in workmanship and materials for a period of six months after purchase by the original owner, provided the compressor is run with synthetic compressor oil - subject to and in accordance with the terms and conditions set forth below: This warranty does not cover damage to the product resulting from improper useage, improper maintenance, neglect of care, alteration or...
  • Seite 10: Warranty Registration

    Warranty Registration This warranty only covers compressors which have been bought from an authorised L&W dealer, set up as a complete unit with frame and engine or electric motor. Compressor Type Serial Number Engine / Motor Number : Compressor Options Date of Purchase Name of L&W Dealer Dealer Address...
  • Seite 11 Remarks for the Operator The fittings (safety equipment) of the particular pressure vessels have been tested. The pressure vessels have to be submitted to an inspection of the local conditions at site by a competent expert before being taken into operation. According to the German pressure vessel regulation §...
  • Seite 12 Cooling Air Inlet Kühlluft Ansaugbereich LW 160 E / LW 225 E Lenhardt & Wagner GmbH Cooling Air Outlet Kühlluft Abströmbereich...
  • Seite 13: Spare Part List

    SPARE PART LIST LW 160 E - LW 190 E L e n h a r d t & W a g n e r G m b H Im Taubenfang 4 64653 Lorsch Germany Tel.: + 49 62 51 - 10 74 0...
  • Seite 14 C O M P R E S S O R B L O C K – L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 15 C O M P R E S S O R B L O C K - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 16 C O M P R E S S O R B L O C K - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 17 C O M P R E S S O R B L O C K - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 18 A I R I N T A K E F I L T E R A S S E M B L Y - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 19 H I G H P R E S S U R E T U B E S - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 20 F I L T E R H O U S I N G / W A T E R S E P A R A T O R - L W 1 6 0 E / L W 1 9 0 E P a r t N o .
  • Seite 21 F I L T E R H O U S I N G / W A T E R S E P A R A T O R - L W 1 6 0 E / L W 1 9 0 E P a r t N o .
  • Seite 22 W A T E R S E P A R A T O R 1 . & 2 . S T A G E - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 23 F R A M E - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t . R e m a r k s LW 160 / 190 210 Lower Frame...
  • Seite 24 F I L L I N G V A L V E A S S E M B L Y - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 25 E L E C T R I C M O T O R - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .
  • Seite 26 E N G I N E H O N D A G X 2 7 0 - L W 1 6 0 E / L W 1 9 0 E P a r t N o . D e s c r i p t i o n Q y t .

Diese Anleitung auch für:

Lw 190 b