Herunterladen Inhalt Inhalt Diese Seite drucken

B) Batteries; Technical Data - VOLTCRAFT IR 650-16D Bedienungsanleitung

Ir-thermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

b) Batteries

You are required by law to return all used batteries (Battery Directive). Batteries must
not be placed in household waste.
Batteries containing hazardous substances are labelled with this symbol to indicate
that disposal in household waste is forbidden. The abbreviations for heavy metals in
batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (indicated on the battery, e.g.
below the trash icon on the left).
Used batteries can be returned to local collection points, our stores or battery retailers.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

15. Technical Data

Power supply ..................................9 V block battery
Temperature range .........................-40 to +650 °C
Resolution .......................................0.1 °C
IR optics ..........................................16:1
Emission level .................................0.1 – 1.00 (adjustable)
Response time ................................150 ms
Laser class .....................................2
Laser wave length ..........................630 – 670 nm
Laser output ....................................<1 mW
Operating conditions .......................0 to +50 °C, 10 – 90 % RH
Storage conditions ..........................-10 to +60 °C, <80 % RH
Dimensions .....................................198 x 112 x 55 mm
Weight ............................................177 g