5 Technical data

Temperature influences
The load cell must always be protected against strong temperature gradients. The technical data
specified apply to statutary calibration duty use within a temperature range of --10°C ... +40°C.
Type (see type code on page 16)
/ Maximum capacity (E
Accuracy class according to OIML R 60
Max. number of load cell verification intervals (n
Min. load cell verification interval (v
Sensitivity (C
)
n
Sensitivity tolerance
Temperature effect on sensitivity (TK
Temperature effect on zero balance (TK
1)
Hysteresis error (d
)
hy
1)
Non-linearity (d
)
lin
Creep (d
) over 30 min.
cr
Input resistance (R
)
LC
Output resistance (R
)
0
Reference excitation voltage (U
Nominal range of excitation voltage (B
Insulation resistance (R
Nominal temperature range (B
Service temperature range (B
Storage temperature range (B
Safe load limit (E
)
L
Breaking load (E
)
d
Lateral load limit (E
)
lq
Permissible dynamic load (F
(vibration amplitude according to DIN 50100)
Deflection at E
(s
max
nom
Maximum capacity (E
max
Weight (G), approx.
Protection class according to EN60529 (IEC529)
Material: Measuring element
2)
Cable fitting
Cable--sheath
1)
The data for Non--linearity (d
values. The sum of these data meets the requirements according to OIML R60.
2)
HLC... / 2.2t; 4.4t: • 4--wire connection cable with colour--code green / black / white / red (see page 8)
3)
BLC...:
Option: Explosion proof version
for use according to declaration of conformity in intrinsically safe circuits of the group EEx ib IIC T4.
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
Capteur de pesage
)
max
)
min
1)
)
C
)
0
)
ref
)
U
)
is
)
T
)
tu
)
tl
)
srel
), approx.
)
2)
), Hysteresis error (d
lin
• Sealing: perbunan; Cable--sheath: polyurethane.
Protection class IP65
HLC... / BLC...
HLC .1 .. / 220kg; 550kg; 1.1t; 1.76t
BLC .1 .. / 220kg; 550kg; 1.1t; 1.76t
)
1000
LC
% of C
0.0285
n
mV/V
%
< ± 0.5000
% of C
< ± 0.0500
n
/ 10K
% of C
< ± 0.0400
n
/ 10K
%
< ± 0.0500
%
< ± 0.0500
%
< ± 0.0500
V
V
GΩ
o
C
o
C
o
C
% of E
max
% of E
max
% of E
max
% of E
max
mm
220kg
550kg
kg
0.9
Stainless steel / Sealing: Neoprene
) and Temperature effect on sensitivity (TK
hy
2)
HLC . .. / 2.2t; 4.4t
D1
3000
0.010
1.94
< ± 0.1000
< ± 0.0140
< ± 0.0140
< ± 0.0170
< ± 0.0170
< ± 0.0166
> 350
350 ± 2
5
5...15
> 5
--10 ... +40
--15 ... +70
--15 ... +85
150
300
100
70
0.5
1.1t
1.76t
0.9
0.9
0.9
3)
IP 67
Stainless steel
2)
PVC

MA.HLC/BLC.0def -- 22.10.99

9
C3
2.2t
4.4t
1.6
2.2
2)
) are typical
C

Werbung