Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning; Wear Parts - Oase ProMax Pressure Well 3000/18 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Malfunction

MAINTENANCE AND CLEANING

W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Before reaching into the water, switch
off the mains voltage of all units in the
water.
• Isolate the unit (disconnect from the
power supply) before carrying out any
work on it.
N O T E
Recommendation on regular cleaning:
• Clean the unit as required but at least
twice per year.
• Do not use aggressive cleaning agents
or chemical solutions as they could at-
tack the housing or impair the function
of the unit.
• Recommended cleaning agent for re-
moving stubborn limescale deposits:
– Pump cleaning agent PumpClean
from OASE.
– Vinegar- and chlorine-free household
cleaning agent.
• After cleaning, thoroughly rinse all parts
in clean water.
16
Cause
Cleaning the non-return valve
Sand can block the non-return valve of the
pump so that it cannot close properly. The
non-return valve has to be cleaned.
Prerequisite:
• The pressure hose and adapter have
been dismantled.
How to proceed:
 D
1. Carefully pull out the non-return valve
with pliers.
2. Thoroughly clean the non-return valve
with clean water.
3. Reassemble in the reverse order.
4. Prior to installing, allow the pump to
convey clear water for a few minutes
(e.g. in a basin) to completely remove
any sand residue. (→ Installation and
connection)

WEAR PARTS

The following components are wear parts
and may only be replaced by the OASE
Service.
• Impeller unit
Remedy
the sand has been com-
pletely flushed out. If the
pump still does not start
up, contact OASE.
− The impeller may only
be replaced by the
OASE Service.
ProMax Pressure Well

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Promax pressure well 6500/105777370896

Inhaltsverzeichnis