5.4

Connecting and installing the control system

The cable harness of the Drum Filter Module contains the connection cables of the signal box, the drum
motor and the rinsing pump.
Connecting
N
Connect the three connectors of the cable harness to the control system sockets. Hand-tighten the
union nuts.
The connections are designed to prevent misconnection.
First flood the container with water, then connect the control system to the mains voltage/power
supply.
Installation
O
Install the control system at least 2 m away from the pond.
Protect the control system from direct sunlight.
The control system is splash-proof and may be exposed to rain.
Installation variants:
Suspended installation of the control system: Either on the mount on the container wall of the
Drum Filter Module or using the threaded hooks in another position.
Push both ground stakes onto the control system and push the ground stakes into the ground.
If the ground is hard:
Protect the control system from knocks/impact.
Push both ground stakes onto the control system.
With light pressure push the ground stakes into the ground to mark the position.
Detach the ground stakes from the control system and drive them into the ground.
Then push the control system onto the stakes.
30648-08-13_GA_ProfiClear_Premiu51 51
- GB -
51
21.08.2013 10:23:04