Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of The Uvc Clarifying Unit; Connecting The Dirt Outlet - Oase ProfiClear Premium Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für ProfiClear Premium:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.2.3

Installation of the UVC clarifying unit

Gravity fed system
The UVC clarifying unit Bitron Gravity is installed in the Individual Module. (→Please refer to the "Bitron
Gravity" and "ProfiClear Premium Individual Module" operating manuals.)
Pump fed system
The Bitron Eco UVC clarifying unit is fitted to the Drum Filter Module.
Remove a screen element in order to access the screws of the sealing plugs. (→Replacing a screen
element)
When two filter pumps are operated, one filter pump is connected to a ∅ 50 mm (2 ") inlet, the other
to the Bitron Eco. (→Connecting the inlet)
How to proceed:
4.
J
1. Remove both sealing plugs.
2. Guide the outlet sockets of the Bitron with flat seals through the holes in the container wall.
3. Screw the adapters onto the outlet sockets and hand-tighten.
4. Screw the 30° inlet curves with cap nuts onto the adapters and hand-tighten.
Ensure that the openings point downward.
5. Follow the instructions in the operating manual to connect the Bitron to the filter pump.
5.2.4

Connecting the dirt outlet

D, E
The coarse dirt that collects in the dirt channel drains away via the DN 110 coarse dirt outlet (top outlet
on the container) on the input side.
Connect a suitable DN 110 pipe and drain the dirty water into the sewer system.
The water in the container can be drained via the DN 75 dirt outlet with slide valve at the bottom of the
container if required (for cleaning, repair, overwintering).
Connect a suitable DN 75 pipe and drain the dirty water into the sewer system.
Route the two DN 75 and DN 110 pipes together into one pipe and drain the dirty water via a DN 110
pipe into the sewer system. This will ensure that the dirty water pipe will be conveniently flushed out with
sufficient pressure.
30648-08-13_GA_ProfiClear_Premiu49 49
- GB -
49
21.08.2013 10:23:04

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis