2. Horizontal installation, tubes down (only recommended for liquid applications)
Figure 3-4
Horizontal orientation, tubes down
3. Horizontal installation, tubes up (only recommended for gas applications)
Figure 3-5
Horizontal orientation; tubes up
Note
Hygienic applications
In 3A and EHEDG certified hygienic applications the flowmeter must be installed vertically as shown in 1.
Installation in a drop line
Installation in a drop line is only recommended if a pipeline reduction or orifice with a smaller cross-section can be installed
to create back-pressure and prevent the sensor from being partially drained while measuring.
Back pressure orifice
On / off valve
Figure 3-6
Installation in drop line
4
SITRANS FCS400 sensor
A5E03649755-02, 03/2012