Herunterladen Inhalt Inhalt Diese Seite drucken

Side Connection - GUTMANN EM 05 Montageanleitung

Vorschau ausblenden Andere Handbücher für EM 05:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
Installation Instructions

Side Connection

1. (For exhaust operation) Prepare a suitable
exhaust airflow in the wall.
2. Drill positions for the fastener holes in the
ceiling on the basis of the suspension points
provided on the hood body using a suitable
drill. Missing dimensions are dependent on
the model and must be measured directly
from the hood. Note the minimum distance
between cooking areas and the underside of
the exhaust hood. (Holes Ø10mm for the
attachment of the exhaust hood) Please
position the exhaust hood in the center of the
cooking area.
3. Drill the holes and insert suitable screw
anchors flush.
4. Before the exhaust hood is suspended,
make sure that the exhaust connection is
located on the correct side.
The exhaust connection can be placed on all
four faces. To do so, remove the metal filter
and the attachment screws from the cover
plate. Remove the cover plate with the
exhaust posts pointed in and attach to the
proper side in the indicated position, replace
the metal filter. S 26.
5. Now screw machine screws into the screw
anchors (Ø10 mm) until they protrude by
about 20 mm. Screw thread guides onto the
machine screws and screw the threaded
pipes onto the machine screws. Hang the
exhaust hood directly on the machine screws
for flush ceiling installation.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis