EN
Assembly preparation / Electrical connection :
WARNING AGAINST ELECTRICAL TENSION !
THERE IS DANGER TO LIFE !
There are energised parts near this symbol. Covers marked with this symbol
may only be removed by an authorised electrician.
•
The electrical connection may only be carried out by an authorised specialist!
•
The statutory regulations and connection conditions of the local electrical supply
company must be observed in full.
•
When the device is connected, a device must be provided which makes it possible to
disconnect the device from the mains with an opening width of at least 3 mm all poles
using a contact. LS switches, fuses and contactors are regarded as suitable dis-
connecting devices. When connecting and repairing the device, disconnect it from
the power supply using one of these devices.
•
The protective conductor must be long enough so that if the strain relief fails, it will
only be subjected to tensile stress after the current-carrying cores of the connecting
cable.
•
The excess cable length must be pulled out of the installation area below the device.
Please make sure that the mains voltage is the same as on the nameplate.
•
•
Complete protection against accidental contact must be ensured by installation.
•
Attention: Incorrect connection can lead to destruction of the power electronics.
•
The device is only approved for permanent installation. It must not be connected with
a safety plug.
Connected loads
Cooker hob mains voltage:
1N~ 220-240V / 32A , 50/60Hz
2N~ 380-415V / 16A , 50/60Hz
Connecting cable available at the factory
•
The hob is equipped with a temperature-resistant connection cable at the factory.
•
Damaged lines may only be replaced by the manufacturer or his customer service.
26