Important safety information
Set up the device safely
Set up the device safely
Set up the device safely
Set up the device safely
Place the device on a flat and even surface- flip the battery
compartment cover and reinsert it to use it as a stand. The device can be hung on a nail
or screw by utilizing the hole on the back side of the case.
Ensure that:
• the device isn't placed on a thick carpet or bed during operation ;
• no direct heat sources (i.e. radiators) influence the device;
• no direct sunlight reaches the device;
• contact with splashing or dripping water must be avoided (don't place any items
filled with liquids, i.e. vases, onto or next to the device);
• the device doesn't stand near magnetic fields (i.e. speakers);
• candles and other open flames must be kept away from this product at all times to
prevent the spread of fire
• no foreign objects penetrate the housing.
• the device is not placed near other devices that use the same frequency (433 MHz)
as this may interfere with signal reception.
Additional information about the outdoor sensor
Additional information about the outdoor sensor
Additional information about the outdoor sensor
Additional information about the outdoor sensor
Select a roofed area to setup your outdoor sensor. Do not let the sensor come into
contact with water or direct sunlight.
- Batteries
Insert the batteries/ rechargeable batteries in the correct polarity. Do not attempt to
recharge non-rechargeable batteries and under no circumstances throw them into fire.
Danger of explosion.
Do not use unequal batteries (old and new, Alkaline and carbon, etc.) simultaneously.
If you will not use the device for a long time, remove the batteries and store the device
in a dry and dust-free place. Improper use of batteries may cause an explosion or
leakage. If the batteries have leaked, use gloves and clean the device thoroughly with
a dry cloth.
Batteries/ rechargeable batteries can be life threatening when swallowed. Store the
batteries where they cannot be reached by small children. If a battery is swallowed,
medical aid must be sought immediately.
Alarm features
In unfavourable conditions your radio-controlled thermo-hygrometer will show different
symbols at the top of the display and emit an audible warning. The audible warning
can be activated by pressing the alarm button on the top of the case. When the alarm
is activated the bell symbol will appear on the display.
risk
risk
increased risk
increased risk
risk
risk
increased risk
increased risk
(face blinks)
(no audible warning)
Comfort display
In favourable indoor climate conditions the comfort symbol will appear on the display.
- 5 -
description
description
description
description
Low humidity / temperature
Low humidity / temperature
Low humidity / temperature
Low humidity / temperature
At low humidity the mucous membranes are drier
and therefore more susceptible to infection.
High humidity / temperature
High humidity / temperature
High humidity / temperature
High humidity / temperature
Increased risk of mould caused by high humidity.
High temperature / humidity
High temperature / humidity
High temperature / humidity
High temperature / humidity
High temperatures strain your body. Ideally, the
indoor temperature should not rise too much,
even at high outdoor temperatures.
Large change in outdoor temperature (±5°C
Large change in outdoor temperature
Large change in outdoor temperature
Large change in outdoor temperature
in in in in one hour
one hour) ) ) )
one hour
one hour
Your radio-controlled thermo-hygrometer warns
you of large changes in the outdoor
temperature.
- 7 -
Setup
Remove the protective film from the display. Open the battery compartment on the
back side of the radio-controlled thermo-hygrometer and insert two 1.5V AAA
R03/LR03 batteries in the correct polarity. Close the battery compartment. The radio-
controlled thermo-hygrometer will now automatically measure the temperature and
humidity indoors. The measurement can be restarted by pressing RESET.
Now open the battery compartment of the radio sensor for outdoor temperature within
the next 3 minutes and insert two 1.5V AA R6/LR6 batteries in the correct polarity.
Close the battery compartment. The sensor will blink when the batteries are inserted. If
the reception is adequate, the radio-controlled thermo-hygrometer will receive the
signal within the next minutes and display the outdoor temperature. Press the TX-button
within the battery compartment of the sensor to restart sensor.
Temperature display
Press IN/OUT to select the indoor or outdoor temperature display. If using more than
one sensor (up to 3), press CHANNEL to select a sensor.
If reception is lost, the radio-controlled thermo-hygrometer will continue to display the
last recorded temperature. Press RESET to start a new reception attempt and then press
the TX-button within the battery compartment of the outdoor sensor.
The device shows the lowest and highest measured temperature and humidity under
MIN-MAX.
Channel selection
If using more than one sensor, press CHANNEL to select a sensor. To display the data
from the sensor that was included with your radio-controlled thermo-hygrometer, select
channel 1 ("CH1") on the display.
Feature chart 0%-54% humidity
10
LO
%
0
°C
5
°C
10
°C
15
°C
20
°C
25
°C
30
°C
(±5°C
(±5°C
(±5°C
35
°C
40
°C
45
°C
50
°C
- 6 -
15
20
25
30
35
%
%
%
%
%
- 8 -
40
45
50
%
%
%

Werbung