Using the dipswitches
Set-up
DS-1
off
DS-2
DS-3
DS-4
DS-5
DS-6
DS-7
DS-8
DS1=off
DS-1 not used and must be switched to Off.
Note about DS-2: DS-2 should be switched "on" (default setting) when no remote panel or
remote on-off switch is used. activate the setting switches DS-3 to DS-8.
DS-2 should also be switched off to use a remote control panel or remote on-off switch.
Battery charge Type
DS-1
off
DS-2
on
DS-3
off
DS-4
off
DS-5
DS-6
DS-7
DS-8
DS3=off,DS4=off
= Type 1 (gel)
DS3=on,DS4=off
= Type 2
DS3=off,DS4=on
= Type 3
DS3=on,DS4=on
= Type 4
DS-1
off
DS-2
on
DS-3
DS-4
DS-5
DS-6
DS-7
DS-8
See note
DS-1
DS-2
DS-3
DS-4
DS-5
DS-6
DS-7
DS-8
Store the settings (DS3-
DS4) by changing the
DS8 switch position off to
on, and then back to off
off
on
x
x
x
x
15