2.4 LED Indications

LED off
LED flashes
LED illuminated
Inverter
inverter
charger
alarm
inverter
charger
alarm
inverter
charger
alarm
Charger
inverter
charger
alarm
inverter
charger
alarm
on
The inverter is switched on and supplies
power to the load. Battery operation.
off
charger only
The inverter is switched on and supplies
on
power to the load.
Pre alarm: overload, or
off
battery voltage low, or
inverter temperature high
charger only
The inverter is switched off.
Alarm: overload, or
on
battery voltage low, or
inverter temperature hig, or
off
DC ripple voltage on battery
charger only
terminal was too high
on
The AC input voltage is switched through
and the charger operates in bulk or
off
absorption mode.
charger only
The AC input voltage is switched through
on
and the charger is switched off.
The battery charger can not reach battery
off
end voltage (bulk protection mode).
charger only