Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy Phoenix MultiPlus Compact 12 | 2000 | 80 Anleitung Seite 14

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

3.3 Requirements
Philips screwdriver (PH2) for removing the front.
Flat screwdriver (0.6x3.5) for connecting the AC leads.
Three-wire cable.
3.4 Connection of Battery cables
In order to fully utilize the full capacity of the product, batteries with sufficient capacity and
battery cables with sufficient cross section should be used. See table.
Recommended
cross section (mm
6 m
Recommended
battery capacity (Ah)
Remark: Internal resistance is the important factor when working with low capacity batteries.
Please consult your supplier or the relevant sections of our book "electricity on board",
downloadable from our website.
Procedure
Proceed as follows to connect the battery cables:
Use an insulated box spanner in order to avoid shorting the battery.
Avoid shorting the battery cables.
Connect the battery cables: the + (red) on the left and the - (black) on the right, to the battery
see Appendix A.
Reverse polarity connection (+ to – and – to +) will cause damage to the Phoenix Multi
Compact.(Safety fuse inside the Multi Compact can be damaged)
Secure the nuts tightly in order to reduce the contact resistance as much as possible.
10
48/2000
24/2000
2
)
35
50
48/2000
24/2000
100 – 400
200 – 500
12/2000
70
12/2000
350 – 1000

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Phoenix inverter compact 48 | 2000Phoenix multiplus compact 24 | 2000 | 50Phoenix inverter compact 12 | 2000Phoenix inverter compact 24 | 2000Phoenix multiplus compact 48 | 2000 | 25

Inhaltsverzeichnis