Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
OBJ_DOKU-30379-003.fm Page 15 Wednesday, June 11, 2014 10:12 AM

Technical Data

Article number
Impact rate
Tool holder
– Round shank
– Hexagon
Max. working pressure for tool
Thread size of hose connection
Inner diameter of hose
Air consumption at no-load
Weight according to EPTA-Procedure 01/2003
Assembly
Connecting the Air Supply (see figure A)
 Ensure that the air pressure is not lower than 6.3 bar
(91 psi) because the pneumatic tool is designed for
this operating pressure.
For maximum performance, the values for the inner hose di-
ameter as well as the connection threads must be adhered to
as listed in the "Technical Data" Table. To maintain the full
performance, only use hoses with a maximum length of 4 m.
The compressed air supplied should be free of foreign materi-
al and moisture to protect the tool from damage, contamina-
tion, and the formation of rust.
Note: The use of a compressed-air maintenance unit is neces-
sary. This ensures proper function of the pneumatic tools.
Observe the operating instructions of the maintenance unit.
All fittings, connecting lines and hoses must be dimensioned
for the pressure and the required air volume.
Avoid restrictions in the air supply, e.g., from pinching, kink-
ing, or stretching!
When in doubt, check the pressure at the air inlet with a pres-
sure gauge with the pneumatic tool switched on.
Connecting the Air Supply to the Pneumatic Tool
– Screw hose fitting 4 into the connection socket at air inlet 3.
To avoid damage to interior valve components of the pneu-
matic tool when screwing hose fitting 4 in or out, it is recom-
mended to counter-hold the projecting connection socket
of air intake 3 with an open-end wrench (size 22 mm).
– Loosen hose clamp 5 of supply-air hose 6, mount the sup-
ply-air hose to hose fitting 4 and retighten the hose clamp.
Note: Always mount the supply-air hose to the pneumatic tool
first, then to the maintenance unit.
Mounting application tools
Inserting a Chisel (0 607 560 500) (see figure B)
– Screw retaining spring 8 to the stop onto tool holder 7.
– Bend hook clip 9 of retaining spring 8 open and insert a
chisel until the shoulder of the chisel is positioned behind
the hook clip.
Bosch Power Tools
Pneumatic chisel hammer Pneumatic needle descaler
0 607 560 500
-1
min
3600
mm
10.2
mm
bar
6.3
psi
G 1/4"
mm
l/s
8.5
cfm
kg
1.0
lbs
2.2
– Release the hook clip 9.
This secures the chisel against falling out.
Changing Needles (0 607 560 502) (see figure C)
– Loosen the pan head screws 12.
– Pull guide sleeve 11 completely away from the needles.
This relieves the spring pressure on the apertured disc 14.
– Remove the apertured disc 14 together with the needles
from the needle holder 13.
– Push the needles out toward the rear and replace them.
– Assemble/mount all components again, tighten all pan
head screws and lock them with their lock nuts.
Operation
Starting Operation
The pneumatic tool works optimally at a working pressure of
6.3 bar (91 psi), measured at the air inlet when the pneumat-
ic tool is switched on.
Starting and Stopping
To save energy, only switch the power tool on when using it.
– To switch on the pneumatic tool, press the On/Off switch
1 and keep it pressed during the working procedure.
– To switch off the pneumatic tool, release the On/Off
switch 1.
Working Advice
Sudden loads cause a sharp drop in speed or a complete stop,
yet do not cause damage to the motor.
When working, prevent idle running of the pneumatic tool.
Always press the chisel or needles firmly against the work-
piece.
Readjusting Needles (0 607 560 502)
– Loosen the pan head screws 12.
– Slide guide sleeve 11 a little further onto needle holder 13.
– Tighten all pan head screws and lock them with their lock
nuts.
English | 15
0 607 560 502
3600
10
6.3
91
91
G 1/4"
10
10
8.5
18
18
2.0
4.4
1 609 92A 0TG | (11.6.14)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

0 607 560 502

Inhaltsverzeichnis