1. Remove cover [7]/[8] as described in
Chapter 6.
Operation with a single fan
2. On the fan, first set up the room air control
RLS RC and then the radio switches
and/or wireless window contacts.
Master/slave network
2. On the master fan, first set up room air
control RLS RC.
3. Then set up the radio switches, wireless
window contacts and other slave fans.
4. Set up radio switches and wireless window
contacts on the slave fans (max. 2 fans).
5. Preconfigure RLS RC control.
6. Carefully press cover [7] (with designer
cover [8]) on to housing [2] until it engages
with the catch ( fig. A).
7. Perform function test with all system
components.
8.1 Tips for setting up wireless
components
● If the RC fan (master or slave unit)
receives a valid set-up telegram from a
unit that has not yet been set up, the data
is evaluated and stored.
● If the unit has already been set up the
telegram is deleted. The process must be
repeated with the unit which is now no
longer set up.
● If nothing is received within 60 seconds,
set-up is ended (LED on fan goes out).
The process must be repeated.
● Invalid set-up telegrams (from non-
supported units) are ignored.

8.2 Master/slave assignment

● A fan automatically becomes a master unit
if it is set to set-up mode and receives a
transmit telegram from a slave fan.
● A fan automatically becomes a slave unit
if it receives a confirmation after sending a
transmit telegram to the master unit.
8. Wireless components – Setting up and deleting │ EN
● If a master fan is set up on a slave fan by
8.3 Wireless components: setting up
and deleting,  Chapter 2.9, Program
levels
Setting fan to set-up mode
1. Hold down set-up button [11] for at least
A transmit telegram must now be received
within 60 seconds. Otherwise set-up mode
is cancelled again.
Room air control RLS RC
The set-up button is on the back of the room
air control
1. Activate set-up mode on the fan.
2. Briefly press the set-up button on the
Setting up radio switch DS RC
The left- and right-hand rockers (on/off and
level 1/2) must be set up separately.
1. Activate set-up mode on the fan.
2. On the radio switch, press the right rocker
If set-up is not successful, the LED flashes
briefly 3 times.
3. Activate set-up mode on the fan.
4. On the radio switch, press the left rocker
mistake, the master status ceases to apply
(and the master unit becomes a slave
unit). This may mean that all system
components need to be re-entered.
2 seconds
> LED flashes, set-up mode is active.
> LED flashes, set-up mode is active.
RLS RC 3 times.
> If set-up is successful the LED will light
up for about 1 second.
> LED flashes, set-up mode is active.
briefly 3 times within 2 seconds.
> If set-up is successful the LED will light
up for about 1 second.
> LED flashes, set-up mode is active.
briefly 3 times within 2 seconds.
> If set-up is successful the LED will light
up for about 1 second.
> If set-up is not successful, the LED
flashes briefly 3 times.