Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Start-Up; Long Fastening Rod - Maico EC 30 E Montage- Und Betriebsanleitung

Deckenfächer
Vorschau ausblenden Andere Handbücher für EC 30 E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Lift up ceiling fan.
Hang rubber roller of fastening rod [20] in
ceiling hook [14].
Undertake electrical connection according
to section 7.3.
Slide canopy [17] towards ceiling and lock
with setting ring [19].

7.3 Electrical connection

Danger to life from electric
shock
Switch the mains fuse off.
DANGER
The cable length of the motor
i
connection cables has also been
designed for units with the long
fastening rod.
Undertake electrical connection according
to wiring diagram (see rear of instructions
or inside of canopy).

7.4 Start-up

Switch the mains fuse on.
Switch ceiling fan on and off. Check
direction of rotation at same time.
EC 30 E and EC 40 D: The impeller must
turn clockwise (viewed from below).
EC 90 B and EC 140 B: The impeller must
turn anti-clockwise (viewed from below).
Note rotation and air direction
NOTICE
arrows.
If the rotation and air direction
is wrong, check the electrical
connection and correct if
necessary.
16

8. Long fastening rod

Danger to life from electric
shock
Switch the mains fuse off.
DANGER
Incorrect installation results in
a danger of injury from falling
unit parts.
DANGER
When installing and also after
dismantling, always use new
lock nuts according to ISO
7042.
If using a long fastening rod (option with
0.5 m or 1 m), the unit must be modified.
Modification may only be undertaken by a
trained electrician.
If ceiling fan has already been fitted, take it
off the ceiling.
Never undertake modification with fan fitted
on the ceiling and unit live.
The length of the connection cables is
designed ex-factory for the long fastening
rod too.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ec 90 bEc 40 dEc 140 b

Inhaltsverzeichnis