 Locate the connecting flange [2] onto the
bolts [6], line it up and press it gently
against the glass.
Danger of injury Schnitt-
verletzungen bei Glasbruch!
 Take care when tightening lock
CAUTION
nuts [8].
Functional problems and
NOTICE
damage to unit caused by
grazing impeller if installation
is carried out incorrectly!
 Do not fit connecting flange [2]
so it is twisted or crushed!
 Use socket spanner [9] to tighten lock nuts
[8] by hand.
7.2 Wall
Carry out installation as described in chapter
7.1 for window installation. Also observe the
following mounting instructions.
If necessary, screw external shutter [1] and
connecting flange [2] to the wall according
to Figure "B".
 Open the lamella of the external shutter [1]
and drill through at the 4 hole positions [Z].
 Drill connecting flange [2] through at the
two hole positions [Y].
 Use suitable mounting material to fit
external shutter [1] to outside of wall.
 Use suitable mounting material to fit
connecting flange [2] to inside of wall.

7.3 Electrical connection

When installing electrics and fitting
i
units, observe the applicable
regulations, particularly DIN VDE
0100 in Germany, and the appropriate
parts of this.
Danger to life from electric
shock
 Switch the mains fuse off.
DANGER
10
Unit damage in the case of
short-circuits
 Insulate any unnecessary
CAUTION
cable cores.
Danger of short-circuits and
damage to units caused by
penetration of condensation if
CAUTION
connecting cable(s) inserted
incorrectly.
 Use a grommet pin to pierce a
round hole in the cable
grommets
[T1] / [T2] required.
 Guide power cable correctly
into terminal box through
cable grommets. Ensure that
the cable grommets tightly
surround the connecting
cables.
Undertake electrical connection according
to Figures "F" and "G".
 Pierce cable grommet [T1].
 Guide power cable [L] into terminal box.
 Fit tension relief [10].
 For EVN 22 R, pierce cable grommet [T2]
and guide connecting cable [7] into terminal
box.
 Connect cables according to wiring
diagram (see page 18 and 19 of the
instructions).
 For EVN 22 P, insert pull-cord of pull-cord
switch [13] correctly into the two guides.
 Put the terminal block cover [4] on and
screw it into place. Ensure the sealing [12]
is fitted correctly.
Position internal housing [3] according to
Figure "G".
 Fit internal housing [3] on top of connecting
flange [2] (pos. ).
 Snap internal housing [3] into place in the
latches below (pos. ). Do not twist it.