Herunterladen Inhalt Inhalt Diese Seite drucken

Addressing The Device - EuroLite 51915420 Bedienungsanleitung

Controller für led trusslight
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Please note, the starting address depends upon which controller is being used.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first device in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first device in the DMX-chain with the DMX-input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last device, the DMX-cable has to be terminated with a terminator. Solder a 120
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last device.

Addressing the device

The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the LED PSU-24V DC will respond to the DMX controller.
Please, be sure that you don't have any overlapping channels in order to control each LED PSU-24V DC
correctly and independently from any other fixture on the DMX-chain.
If several LED PSU-24V DC are addressed similarly, they will work synchronically.
Note:
The mode of DMX 512 data is shown via the display:
The device will automatically detect whether DMX 512 data is received or not. If the data is received, the
display will flash "A.001". If there is no data received at the DMX-input, the display will show "A.001".
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
To define the starting address, you have to be in DMX-mode. Press MODE until the display indicates A.001.
Set an address between 001 and 512 via the UP and DOWN buttons.
19/22
00043178.DOC, Version 1.2