Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx-Controlled Operation; Addressing The Device; Dmx-Protocol; Blackout - EuroLite LED Panel RGB DMX 230 V Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DMX-CONTROLLED OPERATION

You can control the LED PANELS individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
For DMX-controlled operation set DIP Switches 1 and 10 to ON. (This setting is also used to determine the
Slave device).

Addressing the device

Each device occupies 5 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches
as set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Controlling:
After having addressed all LED PANELS, you may now start operating these via your lighting controller.

DMX-protocol

Channel 1
Red
0 - 255
0-100 %
Channel 2
Green
0 - 255
0-100 %
Channel 3
Blue
0 - 255
0-100 %
Channel 4
Dimmer
0 – 255
0-100 %
Channel 5
Flash
0 - 10
No function
11 - 255
0-100 % with increasing speed

Blackout

In order to select Blackout, set DIP Switch 10 to ON and DIP Switch 1 to 9 to OFF.