Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Fuse; Technical Specifications - EuroLite TC-150 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
DMX-control-channels:
DMX-512-connection:
Sound-control:
Flash-rate:
Number of colours:
Number of gobos:
Dimensions (LxWxH):
Weight:
Fitting lamp:
PHILIPS CDM-T 150W/830 G12
OSRAM HQI-T150/NDL PRO 6000h 230/150W G12
Topspot HIT 230V/150W G-12 6000h nw
GE CMH 150/T G12 6000h
OMNILUX OMD 230V/150W G12 6000h 4200K
Recommended controllers:
EUROLITE DMX Operator
Wizard-512 DMX-Software + Interface
Wizard-1024 DMX-Software + Interface
Maximum ambient temperature t
Maximum housing temperature t
Fuse:
Please note: Every information is subject to change without prior notice. 06/02 ©
230 V/50 Hz
330 W
3
3-pin XLR
via built-in microphone
1-7 Hz
14 dichroic + white
10 gobos, 5 beam-shapers
315 x 270 x 285 mm
7 kg
No. 91014045
No. 91201794
No. 91201797
No. 91201800
No. 91201805
No. 70064520
No. 51860101
No. 51860110
45° C
:
a
(steady state):
60° C
B
F 3.15 A, 250 V