DMX512 control

The wires must not come into contact with each other, otherwise
the devices will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
For the plug connection between controller and the device please use the enclosed adapter cable. For this
purpose, connect the DMX input plug of the device with the adapter cable. Fasten the locknuts on the
connectors. Then connect the 3-pin XLR-plugs of the adapter cable with the 3-pin XLR-connectors of the
controller.
To connect one fixture with another, connect the DMX output connector of the first fixture in the DMX chain
to the DMX input plug of the next fixture. Always connect one output with the input of the next fixture until all
fixtures are connected. If required, you can also use the 5 m extension cable (available accessory).
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
The DMX connection can be made via DMX adapters or special DMX connection cables. The important thing
about this is that the connection is always sufficiently isolated against humidity.