Pre-Operation Safety Inspection

P
-O
RE
PERATION
NOTE: Carefully read, understand and follow all safety rules, operating instructions, labels and National Safety
Instructions/Requirements. Perform the following steps each day before use.
1. Open modules and inspect for damage, fluid leaks or missing parts.
2. Check the level of the
hydraulic fluid with the plat-
form fully lowered. The
hydraulic reservoir is
located at the rear of the
machine. The fluid level
should be visible through
the side of the reservoir,
and must be between the
MIN and MAX lines (see
Figure 3). Add hydraulic
fluid if necessary.
3. Check that fluid level in the batteries is correct (See "Battery Maintenance" on page 13).
4. Verify that batteries are charged.
5. Check that A.C. extension cord has been disconnected from the plug in the left Chassis
Module, and that the module doors are closed and locked.
6. Check that all guardrails are in place and all fasteners are properly tightened.
7. Inspect the machine thoroughly for cracked welds and structural damage, loose or missing hardware,
hydraulic leaks, damaged control cable, loose wire connections and wheel bolts.