Herunterladen Inhalt Inhalt Diese Seite drucken

ACO Lipumax-P Gebrauchsanleitung Seite 131

Vorschau ausblenden Andere Handbücher für Lipumax-P:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Numbers in brackets „()", see diagram of the grease separator (example equipment level
3),
page 14: Figure: „Lipumax P-DA".
Fault
Cause(s)
Odour nuisance in
Odour trap (5) without water trap
normal operation
Seal of the cover of the raising system
(31) is damaged
Control (9) without power supply
Automatic operation is switched off
Emergency Stop button (remote control,
33) pressed
No freshwater supply (on site)
HP pump for inner
HP pump not switched on
cleaning (11) not
Current consumption too high
functioning
(automatic switching off)
Emergency Stop button (remote control,
33) pressed
HP monitor is defective
Control (9) without
Power supply
Automatic mode not
switched on
HP pump for inner
Filter in the inlet pipe of the HP pump is
cleaning (11) builds
blocked
up too little
pressure
HP orbital cleaning
HP orbital cleaning head dirty
head (17) does not
Power supply interrupted
turn
HP orbital cleaning head is defective
HP orbital cleaning
Outlet nozzles in the HP orbital cleaning
head (17) without
head blocked
water outlet
HP orbital cleaning head is defective
Control (9)
Control without power supply
Emergency Stop button (remote control,
33) pressed
Program error
Grease separators Lipumax-P -B, -D, -DM, -DA
Action
Open the ball valve of the manual filling
device (4)
For operation with control (9):
Set "Refilling GV" in the menu
Check the solenoid valve of the filling
device (4), replace if necessary
Replace seals
Restore power supply (electrician)
Switch on automatic operation
Unlock emergency stop button
Restore freshwater supply (on site)
Switch on HP pump
Keep "reset/enter" button pressed for
approx. 2 seconds.
If fault persists:
Contact ACO Service
Unlock emergency stop button
Replace HP monitor
Restore power supply
(electrician)
Switch on automatic mode
Clean filter in the inlet pipe
Clean HP orbital cleaning head
Restore power supply (electrician)
Replace HP orbital cleaning head
Clean outlet nozzles
Replace HP orbital cleaning head
Restore power supply (electrician)
Unlock emergency stop button
Pull the mains plug of the control out of
the CEE socket and then plug in again
after approx. 15 seconds
Troubleshooting
131/ 144

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für ACO Lipumax-P

Diese Anleitung auch für:

Lipumax-bLipumax-daLipumax-dLipumax-dm

Inhaltsverzeichnis